{"id":6042,"date":"2019-01-30T12:23:55","date_gmt":"2019-01-30T11:23:55","guid":{"rendered":"https:\/\/www.boc.de\/watchguard-info-portal\/?p=6042"},"modified":"2025-10-21T13:59:44","modified_gmt":"2025-10-21T11:59:44","slug":"fireware-12-3-1","status":"publish","type":"post","link":"https:\/\/wordpress.boc.de\/watchguard-info-portal\/2019\/01\/fireware-12-3-1\/","title":{"rendered":"Fireware 12.3.1 jetzt verf\u00fcgbar"},"content":{"rendered":"<p>Seit dem 25. Januar verf\u00fcgbar: Fireware 12.3.1 und\u00a0WatchGuard System Manager 12.3.1.<\/p>\n<p><!--more--><\/p>\n<p>Die Version 12.3.1 ist ein Maintenance-Release, d.h. es gibt nur kleine \u00c4nderungen:<\/p>\n<ul>\n<li>Erweiterungen verschiedener Security Services<\/li>\n<li>Erweiterungen und Fehlerbehebungen im Gateway Wireless Controller<\/li>\n<\/ul>\n<p>Eine \u00dcbersicht der letzten Fireware Releases inkl. deren Neuerungen finden Sie <a href=\"https:\/\/www.boc.de\/watchguard-info-portal\/supportinfos\/fireware-release-neuerungen\/\" target=\"_blank\" rel=\"noopener\">HIER<\/a>.<\/p>\n<h5>Download der Software aus dem WatchGuard Support Center:<\/h5>\n<ul>\n<li>im\u00a0<a href=\"https:\/\/software.watchguard.com\/\" target=\"_blank\" rel=\"noopener\">WatchGuard Support Center<\/a>\u00a0das entsprechende Modell ausw\u00e4hlen um anschlie\u00dfend die gew\u00fcnschte Fireware downloaden zu k\u00f6nnen<\/li>\n<li><a href=\"http:\/\/cdn.watchguard.com\/SoftwareCenter\/Files\/WSM\/12_3_1\/wsm_12_3_1.exe\" target=\"_blank\" rel=\"noopener\">WatchGuard System Manager v12.3.1 (exe)<\/a><\/li>\n<\/ul>\n<p>Im Folgenden die Originalmeldung von WatchGuard:<\/p>\n<h3>Enhancements and Resolved Issues in Fireware and WSM\u00a012.3.1 Update 1<\/h3>\n<ul>\n<li value=\"1\">The update on January 25th resolves an issue with Fireware v12.3.1 in which the Gateway Wireless Controller could not manage most AP\u00a0devices.\u00a0<span class=\"NumContinued\">[FBX-15365, FBX-15183]<\/span><\/li>\n<\/ul>\n<h3>Enhancements and Resolved Issues in Fireware and WSM\u00a012.3.1<\/h3>\n<h5>General<\/h5>\n<ul>\n<li value=\"1\">This release resolves an issue with FireCluster log messages that caused Traffic Monitor to fail to display any log messages.\u00a0<span class=\"NumContinued\">[FBX-14840]<\/span><\/li>\n<li value=\"2\">The Firebox no longer fails to send log messages to Dimension or a WatchGuard Log Server after you enable FIPS mode.\u00a0<span class=\"NumContinued\">[FBX-13318]<\/span><\/li>\n<li value=\"3\">This release resolves a kernel crash on the Firebox T30, T50, T35, M200 and M300 models.\u00a0<span class=\"NumContinued\">[FBX-14699]<\/span><\/li>\n<\/ul>\n<h5>Authentication<\/h5>\n<ul>\n<li value=\"1\">SSO Exceptions configured as a host range are no longer restricted to a single class C (\/24) network.\u00a0<span class=\"NumContinued\">[FBX-14459, FBX-14753]<\/span><\/li>\n<li value=\"2\">This release resolves an issue with Event Log Monitor threads not responding to user queries.<span class=\"NumContinued\">\u00a0[FBX-14317]<\/span><\/li>\n<\/ul>\n<h5>Networking<\/h5>\n<ul>\n<li value=\"1\">The Firebox System Manager SD-WAN status page now correctly displays failback options.\u00a0<span class=\"NumContinued\">[FBX-14639]<\/span><\/li>\n<li value=\"2\">The new cluster master now correctly updates with routes from OSPF after a FireCluster failover event.\u00a0<span class=\"NumContinued\">[FBX-14909]<\/span><\/li>\n<li value=\"3\">This release resolves an issue with PPPoE negotiation after FireCluster failover when a secondary network IP\u00a0address is configured on the interface.\u00a0<span class=\"NumContinued\">[FBX-13499]<\/span><\/li>\n<li value=\"4\">This release resolves a localization issue in Japanese-language Web UI in the TCP MTU\u00a0Probing configuration.\u00a0<span class=\"NumContinued\">[FBX-10285]<\/span><\/li>\n<li value=\"5\">The Firebox now correctly sends diagnostic log messages for Link Monitor.<span class=\"NumContinued\">\u00a0[FBX-13764]<\/span><\/li>\n<li value=\"6\">This release corrects an issue that caused several CLI\u00a0diagnostic commands for FQDN\u00a0to fail.\u00a0<span class=\"NumContinued\">[FBX-13834]<\/span><\/li>\n<li value=\"7\">You can now add domains that include underscore characters to DNS forwarding rules.\u00a0<span class=\"NumContinued\">[FBX-14012]<\/span><\/li>\n<li value=\"8\">This release resolves an issue in which a flood of broadcast packets caused excessive memory usage.\u00a0<span class=\"NumContinued\">[FBX-14439]<\/span><\/li>\n<\/ul>\n<h5>VPN<\/h5>\n<ul>\n<li value=\"1\">IKEv2 multi-wan VPN failback now works correctly when one side of Branch Office VPN is behind a NAT device.\u00a0<span class=\"NumContinued\">[FBX-14842]<\/span><\/li>\n<\/ul>\n<h5>Centralized Management<\/h5>\n<ul>\n<li value=\"1\">You can now assign user roles in Management Server.\u00a0<span class=\"NumContinued\">[FBX-14816]<\/span><\/li>\n<li value=\"2\">This release resolves an issue that caused managed Firebox templates to fail with the error message: Invalid Configuration.\u00a0<span class=\"NumContinued\">[FBX-14881]<\/span><\/li>\n<\/ul>\n<h5>Proxies and Services<\/h5>\n<ul>\n<li value=\"1\">The Firebox now correctly registers external secondary IP addresses when you enable DNSWatch.<span class=\"NumContinued\">\u00a0[FBX-14763]<\/span><\/li>\n<li value=\"2\">This release resolves an IMAP proxy crash.\u00a0<span class=\"NumContinued\">[FBX-14123]<\/span><\/li>\n<li value=\"3\">This release introduces APT scanning for objects identified as\u00a0<span class=\"Input\">suspicious<\/span>\u00a0by Intelligent AV.<span class=\"NumContinued\">\u00a0[FBX-14716]<\/span><\/li>\n<\/ul>\n<h5>Certificates<\/h5>\n<ul>\n<li value=\"1\">The Firebox now correctly labels Certificate Signing Requests for the Proxy Authority by that name instead of Proxy Server.\u00a0<span class=\"NumContinued\">[FBX-14134, FBX-13884]<\/span><\/li>\n<li value=\"2\">You can now import a certificate with an Elliptical Curve (EC) private key.\u00a0<span class=\"NumContinued\">[FBX-14754]<\/span><\/li>\n<\/ul>\n<h5>Firebox Integrations<\/h5>\n<ul>\n<li value=\"1\">You can no longer specify invalid values for Memory Usage in a Tigerpaw configuration.\u00a0<span class=\"NumContinued\">[FBX-13881]<\/span><\/li>\n<\/ul>\n<h5>Gateway Wireless Controller and WatchGuard APs<\/h5>\n<ul>\n<li value=\"1\">You can now manually disconnect wireless clients in Gateway Wireless Controller in Firebox System Manager.\u00a0<span class=\"NumContinued\">[FBX-15043]<\/span><\/li>\n<li value=\"2\">The Gateway Wireless Controller now indicates the AP power source detected by the Access Points which support detection.\u00a0<span class=\"NumContinued\">[FBX-14035, FBX-14662, FBX-14661]<\/span><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Seit dem 25. Januar verf\u00fcgbar: Fireware 12.3.1 und\u00a0WatchGuard System Manager 12.3.1.<\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[122],"tags":[522,425,102,137],"class_list":["post-6042","post","type-post","status-publish","format-standard","hentry","category-watchguard-software-release-news","tag-fireware-12-3-1","tag-fireware-12-x","tag-fw-release","tag-update"],"_links":{"self":[{"href":"https:\/\/wordpress.boc.de\/watchguard-info-portal\/wp-json\/wp\/v2\/posts\/6042"}],"collection":[{"href":"https:\/\/wordpress.boc.de\/watchguard-info-portal\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/wordpress.boc.de\/watchguard-info-portal\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/wordpress.boc.de\/watchguard-info-portal\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/wordpress.boc.de\/watchguard-info-portal\/wp-json\/wp\/v2\/comments?post=6042"}],"version-history":[{"count":5,"href":"https:\/\/wordpress.boc.de\/watchguard-info-portal\/wp-json\/wp\/v2\/posts\/6042\/revisions"}],"predecessor-version":[{"id":29503,"href":"https:\/\/wordpress.boc.de\/watchguard-info-portal\/wp-json\/wp\/v2\/posts\/6042\/revisions\/29503"}],"wp:attachment":[{"href":"https:\/\/wordpress.boc.de\/watchguard-info-portal\/wp-json\/wp\/v2\/media?parent=6042"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/wordpress.boc.de\/watchguard-info-portal\/wp-json\/wp\/v2\/categories?post=6042"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/wordpress.boc.de\/watchguard-info-portal\/wp-json\/wp\/v2\/tags?post=6042"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}